ERGO
Opdatering af software

Træningsvideoer
Kun for serviceteknikere.

Opdatering: HMI via USB

Opdatering: PLC via SD

HMI

Version 2025-06-19

  • Optimized the Recipe Manager
  • Updated the OL parameters: OL1, OL2 & OL3

Version 2025-02-14

  • We have added Dutch and Swedish language variants

Version 2024-10-02

  • Adding an extra page for recovery software for FI
  • When export of log files, software versions will be available inside log files as a parameter
  • When looking in the logs directly on the mixer, all software versions are shown in the upper left corner of the HMI

Version 2024-08-30

  • Added a stir button for 20 RPM constant rotation; this is a button that overrules any other speed setting. When disabling the button, it’ll continue with the previous speed setting.
  • Added a Mexican flag for the US market; no changes is added from the Spanish version other than the flag.
  • We have moved the HMI Update button a step further out, so you don’t need the master code for the mixer to update the HMI.
  • Language text starting with High Case
  • Recipe button in setting interlock in manual operation new look
  • Slow speed button blink when active
  • Change speed 1-4 blocked in slow speed mode
  • US units in Mex
  • Communication error when no connection to FI
  • Minor changes in the Log files read
  • Moved HMI update button 2 layers out so you don’t need the master code to software update the HMI
  • Chanced numbers of characters for the main name of a receipt from 10 to 32 characters on total
  • Added polish as a language
  • Reset Lift motor by pressing the pop up box
  • Liftmotor Cooldown time from changed to 300 sec.

Version 2024-02-01

  • New user interface and redesign of graphical interface for a better user interaction.

PLC

2024- 08-30 > 2024-10-02

  • Changes to reading parameters for the HMI for correct logging. recovery software for the FI

Version 2024-08-30

  • On 140/150, small parameter changes to the FI via PLC
  • Changed minimum speed to speed to 20 RPM’s in recipes
  • Solving the Bus Timeout E100 Error
  • The mixer now auto select size and voltage of the mixer

Version 2024- 08-13 > 2024-08-30

  • User interaction regarding to reset Lift motor
  • Cooldown time from 120 to 300 sec.

Version 2024-02-01

  • Big redesign of user interface and communication between HMI and PLC

TRIN 1
Sådan formaterer og kopierer du softwaren

BEMÆRK!

Når du kopierer software, skal USB-stick og SD-kortet være FAT32-formateret.

Brug ikke USB/SD større end 32 GB.

  1. Indsæt USB-stick / SD-kort
  2. Naviger til drev
  3. Højreklik på drevet
  4. Vælg “Format”
  5. Vælg “FAT32” under filsystem i dialogboksen
  6. Klik på “Start”
  7. Kopier derefter softwaren/mappen til den formaterede USB/SD.
  1. Indsæt USB-stick / SD-kort
  2. Åbn APP’en “Diskværktøj”
  3. Naviger til drev
  4. Højreklik på drevet
  5. Vælg “Earse”
  6. Vælg “FAT32”
  7. Klik på “Slet”
  8. Kopier derefter softwaren/mappen til den formaterede USB/SD.

HMI - på et USB-stik

PLC - På et SD-kort

TRIN 2
Sådan opdaterer du på ERGO

Opdater HMI via USB på ERGO:

Opdater PLC via SD på ERGO'en.

VIGTIGT!

Efter opdateringen skal du fjerne USB og SD, før du genstarter maskinen.

Udviklet til ERGO-serien
60, 100 og 140 (150 US)

Search Webshop Products
×

B2B webshop - Distributor partners

Log ind

Not a B2B webshop + RMA user?

Notice – Only for current B2B distributor partners

Siden 1915

B2B-webshop til distributørpartnere

Log ind

Ikke B2B webshop + RMA bruger?

Bemærk – Kun for nuværende B2B distributør partnere

This site is registered on wpml.org as a development site. Switch to a production site key to remove this banner.