ERGOOpdatering af software
Træningsvideoer
Kun for serviceteknikere.
Opdatering: HMI via USB
(Latest version: 2025-06-19)
Arkiv - HMI
Opdatering: PLC via SD
(Latest version: 2024-10-02)
Arkiv - PLC
HMI
Version 2025-06-19
- Optimized the Recipe Manager
- Updated the OL parameters: OL1, OL2 & OL3
Version 2025-02-14
- We have added Dutch and Swedish language variants
Version 2024-10-02
- Adding an extra page for recovery software for FI
- When export of log files, software versions will be available inside log files as a parameter
- When looking in the logs directly on the mixer, all software versions are shown in the upper left corner of the HMI
Version 2024-08-30
- Added a stir button for 20 RPM constant rotation; this is a button that overrules any other speed setting. When disabling the button, it’ll continue with the previous speed setting.
- Added a Mexican flag for the US market; no changes is added from the Spanish version other than the flag.
- We have moved the HMI Update button a step further out, so you don’t need the master code for the mixer to update the HMI.
- Language text starting with High Case
- Recipe button in setting interlock in manual operation new look
- Slow speed button blink when active
- Change speed 1-4 blocked in slow speed mode
- US units in Mex
- Communication error when no connection to FI
- Minor changes in the Log files read
- Moved HMI update button 2 layers out so you don’t need the master code to software update the HMI
- Chanced numbers of characters for the main name of a receipt from 10 to 32 characters on total
- Added polish as a language
- Reset Lift motor by pressing the pop up box
- Liftmotor Cooldown time from changed to 300 sec.
Version 2024-02-01
- New user interface and redesign of graphical interface for a better user interaction.
PLC
2024- 08-30 > 2024-10-02
- Changes to reading parameters for the HMI for correct logging. recovery software for the FI
Version 2024-08-30
- On 140/150, small parameter changes to the FI via PLC
- Changed minimum speed to speed to 20 RPM’s in recipes
- Solving the Bus Timeout E100 Error
- The mixer now auto select size and voltage of the mixer
Version 2024- 08-13 > 2024-08-30
- User interaction regarding to reset Lift motor
- Cooldown time from 120 to 300 sec.
Version 2024-02-01
- Big redesign of user interface and communication between HMI and PLC
TRIN 1Sådan formaterer og kopierer du softwaren
BEMÆRK!
Når du kopierer software, skal USB-stick og SD-kortet være FAT32-formateret.
Brug ikke USB/SD større end 32 GB.
- Indsæt USB-stick / SD-kort
- Naviger til drev
- Højreklik på drevet
- Vælg “Format”
- Vælg “FAT32” under filsystem i dialogboksen
- Klik på “Start”
- Kopier derefter softwaren/mappen til den formaterede USB/SD.
- Indsæt USB-stick / SD-kort
- Åbn APP’en “Diskværktøj”
- Naviger til drev
- Højreklik på drevet
- Vælg “Earse”
- Vælg “FAT32”
- Klik på “Slet”
- Kopier derefter softwaren/mappen til den formaterede USB/SD.
HMI - på et USB-stik
PLC - På et SD-kort
TRIN 2Sådan opdaterer du på ERGO
Opdater HMI via USB på ERGO:
Opdater PLC via SD på ERGO'en.
VIGTIGT!
Efter opdateringen skal du fjerne USB og SD, før du genstarter maskinen.